Main functions ofthe system:
1. This product uses 3D visualization technology, during intubation, human organs can be truly seen, and chest beating can be simulated during
defibrillation
2. Support customized cases. Users can freely simulate various medical scenarios and support theoretical knowledge management
3. Support custom test forms, users can add any type of test forms, such as blood routine, urine routine, etc
4. Support intubation training and assessment
5. Support customized CPR parameters, CPR training, CPR assessment and CPR practice
6. Simulated and real data monitoring of ECGII, Pleth, APB, CO2, CVP, c.t. emp, p.t. emp and other 18 projects
7. Support real defibrillation equipment and ECG monitor
8. Support online examination, freely combine CPR, intubation, defibrillation, test questions to specify the required papers, support A4 printing and
wireless printer connection
9. As many as 25 types of ECG waveforms, 24 types of lung sounds, 42 types of heart sounds, 5 types of intestinal sounds, 6 types of breathing
patterns are built in
10. Support for custom events, miscellaneous and ABC are free to add events
11.Support drug use and drug administration. Can be free to add or remove drugs, can choose static drip, static injection, subcutaneous,
intramuscular injection, anal plug, injection pump, infusion pump and other ways of medication
12. Support CPR, intubation, and case replay
13. ~kManikin support two system: support computer (Windows) tablet (Android) to facilitate users to operate under multiple systems, Manikin
built—in Bluetooth function, any computer with Bluetooth function or tablet wireless connection real—time regulation.
Products main function:
~kSigns that need to be used with optional accessories to achieve the
function
Head and neck:
- obsen/e the pupil, one side normal, one side dilated.
- can simulate the status of ainivay foreign body infarction: pharyngeal
foreign body obstruction, main ain/vay infarction.
- carotid pulse.
' breathing patterns: normal breathing, bradypnea, tachypnea, shallow
breathing, deep breathing, cuthmore breathing, tidal breathing,
intermittent breathing, sigh like breathing, irregular breathing, apnea.
- voice: including noise, laughter, moaning, coughing, wheezing, and chief
complaints.
- ainivay management: realistic mouth, nose, tongue, gingiva, throat,
esophagus, epiglottis, trachea (simulated ain/i/ay diameter: 9mm); Can
be intubated through the orotracheal tube, suction sputum.
- can simulate the obstruction state of ain/vay foreign body (pharynx and
main ain/vay obstruction); Tracheotomy can be performed; After the
intubation was too deep, only the right lung was ventilated.
The chest:
- simulated human organs include: double lungs, stomach, bladder and
rectum, double lungs for ventilation, bladder and rectum for instillation or
drainage of liquids.
~ simulate spontaneous breathing with chest fluctuation, which can realize
bilateral, left unilateral and right unilateral chest fluctuation.
- both sides can perform puncture drainage and puncture drainage.
~ femoral pulse.
- auscultation sounds: including heart sounds, breath sounds and intestinal
sounds; Among them, normal heart sounds and breath sounds can
automatically produce corresponding changes with monitor heart rate
and breathing frequency.
- gastric catheter insertion: gastric lavage and gastrointestinal
decompression can be performed to support auscultation of the
abdomen to detect the position of the catheter. Gastric juice can be
pumped out after successful intubation.
- vital signs monitor: ecg, heart rate, respiratory rate, blood pressure, body
temperature, oxygen saturation, end—expiratory CO2 partial pressure,
etc.; Flash can simulate convulsive state through software.
- mimic skin color: normal, central cyanosis, peripheral cyanosis, mixed
cyanosis, pale.
- catheterization: male/female perineum can be replaced for male/female
catheterization.
- CPR: support mouth—to—mouth, mouth—to—nose, simple respirator
mouth—to—mouth (BVM), tracheal intubation and other ventilation
methods, electronically monitor ainrvay opening state, tracheal insertion
depth, number and volume of air blowing, number and frequency of
compressions, position and depth of compressions, and automatically
determine the ratio of compressions to artificial respiration
- AED, defibrillation and pacing: multimedia animation shows the AED,
defibrillation process.
~kReal defibrillation and pacing: it can be used together with the self-
provided real defibrillation pacemaker to achieve real defibrillation and
pacing functions.
~kECG monitoring: it can be used together with the self—provided true
ECG monitor to realize ECG monitoring.
*Simulated ECG monitoring: it can be combined with KAR/J116 multi-
parameter simulated ECG monitor to realize the function of simulated
main ECG monitoring.
*Simulated defibrillation, pacing: with KAR/J980 matching use, can
choose defibrillation energy, maximum defibrillation energy up to 36OJ.
Legs:
- manual blood pressure measurement arm that simulates the blood
pressure measurement process with Korktkoff sound.
- venipuncture/infusion: arm vein, femoral vein, dorsal foot vein.
- skin care.
- intramuscular injection: bilateral deltoid muscle and bilateral lateral
femoral flesh injection.
- bone marrow puncture: tibia, obvious body surface markers, simulated
bone marrow outflow.
- movable cen/ical, shoulder, wrist, knee and ankle joints; Can be placed
into a sitting, lying and other positions.