上海康人医学仪器设备有限公司

KANGRENDeveloping Medical Education

Digital training system for newborn's comprehensive first aid skills (ACLS advanced life suppoit, computer control)

KAR/ACLS1500

KAR/ACLS1500
TEL

021-64728431

 Product Display
   Product function

Main functions ofthe system:

1. This product uses 3D visualization technology, during intubation, human organs can be truly seen, and chest beating can be simulated during

defibrillation

2. Support customized cases. Users can freely simulate various medical scenarios and support theoretical knowledge management

3. Support custom test forms, users can add any type of test forms, such as blood routine, urine routine, etc

4. Support intubation training and assessment

5. Support customized CPR parameters, CPR training, CPR assessment and CPR practice

6. Simulated and real data monitoring of ECGII, Pleth, APB, CO2, CVP, c.t. emp, p.t. emp and other 18 projects

7. Support real defibrillation equipment and ECG monitor

8. Support online examination, freely combine CPR, intubation, defibrillation, test questions to specify the required papers, support A4 printing and

wireless printer connection

9. As many as 25 types of ECG waveforms, 24 types of lung sounds, 42 types of heart sounds, 5 types of intestinal sounds, 6 types of breathing

patterns are built in

10. Support for custom events, miscellaneous and ABC are free to add events

11.Support drug use and drug administration. Can be free to add or remove drugs, can choose static drip, static injection, subcutaneous,

intramuscular injection, anal plug, injection pump, infusion pump and other ways of medication

12. Support CPR, intubation, and case replay

13. ~kManikin support two system: support computer (Windows) tablet (Android) to facilitate users to operate under multiple systems, Manikin

built—in Bluetooth function, any computer with Bluetooth function or tablet wireless connection real—time regulation.

Products main function:

~kSigns that need to be used with optional accessories to achieve the

function

Head and neck:

- obsen/e the pupil, one side normal, one side dilated.

- can simulate the status of ainivay foreign body infarction: pharyngeal

foreign body obstruction, main ain/vay infarction.

- carotid pulse.

' breathing patterns: normal breathing, bradypnea, tachypnea, shallow

breathing, deep breathing, cuthmore breathing, tidal breathing,

intermittent breathing, sigh like breathing, irregular breathing, apnea.

- voice: including noise, laughter, moaning, coughing, wheezing, and chief

complaints.

- ainivay management: realistic mouth, nose, tongue, gingiva, throat,

esophagus, epiglottis, trachea (simulated ain/i/ay diameter: 9mm); Can

be intubated through the orotracheal tube, suction sputum.

- can simulate the obstruction state of ain/vay foreign body (pharynx and

main ain/vay obstruction); Tracheotomy can be performed; After the

intubation was too deep, only the right lung was ventilated.

The chest:

- simulated human organs include: double lungs, stomach, bladder and

rectum, double lungs for ventilation, bladder and rectum for instillation or

drainage of liquids.

~ simulate spontaneous breathing with chest fluctuation, which can realize

bilateral, left unilateral and right unilateral chest fluctuation.

- both sides can perform puncture drainage and puncture drainage.

~ femoral pulse.

- auscultation sounds: including heart sounds, breath sounds and intestinal

sounds; Among them, normal heart sounds and breath sounds can

automatically produce corresponding changes with monitor heart rate

and breathing frequency.

- gastric catheter insertion: gastric lavage and gastrointestinal

decompression can be performed to support auscultation of the

abdomen to detect the position of the catheter. Gastric juice can be

pumped out after successful intubation.

- vital signs monitor: ecg, heart rate, respiratory rate, blood pressure, body

temperature, oxygen saturation, end—expiratory CO2 partial pressure,

etc.; Flash can simulate convulsive state through software.

- mimic skin color: normal, central cyanosis, peripheral cyanosis, mixed

cyanosis, pale.

- catheterization: male/female perineum can be replaced for male/female

catheterization.

- CPR: support mouth—to—mouth, mouth—to—nose, simple respirator

mouth—to—mouth (BVM), tracheal intubation and other ventilation

methods, electronically monitor ainrvay opening state, tracheal insertion

depth, number and volume of air blowing, number and frequency of

compressions, position and depth of compressions, and automatically

determine the ratio of compressions to artificial respiration

- AED, defibrillation and pacing: multimedia animation shows the AED,

defibrillation process.

~kReal defibrillation and pacing: it can be used together with the self-

provided real defibrillation pacemaker to achieve real defibrillation and

pacing functions.

~kECG monitoring: it can be used together with the self—provided true

ECG monitor to realize ECG monitoring.

*Simulated ECG monitoring: it can be combined with KAR/J116 multi-

parameter simulated ECG monitor to realize the function of simulated

main ECG monitoring.

*Simulated defibrillation, pacing: with KAR/J980 matching use, can

choose defibrillation energy, maximum defibrillation energy up to 36OJ.

Legs:

- manual blood pressure measurement arm that simulates the blood

pressure measurement process with Korktkoff sound.

- venipuncture/infusion: arm vein, femoral vein, dorsal foot vein.

- skin care.

- intramuscular injection: bilateral deltoid muscle and bilateral lateral

femoral flesh injection.

- bone marrow puncture: tibia, obvious body surface markers, simulated

bone marrow outflow.

- movable cen/ical, shoulder, wrist, knee and ankle joints; Can be placed

into a sitting, lying and other positions.


Recommend

Service Hotline

021-64728431